Category:
Gripper_Vacuum
Nihon PISCO
Product Feature
- Vacuum grippers suitable for transfer of large workpieces.
- 2 types of suction surface are available: whole surface sponge type and aligned vacuum pads type.
- Vacuum generator built-in type and vacuum pump compatible type are available.
- Vacuum generator built-in type secures max. suction flow rate: 760L/min (*).
* Value for 3 built-in ejectors specification.
Official product page
Specification
Purchase Information
Compatibility
Specification
Item | VMG | ||||||||
Type | Whole Surface Sponge type | Aligned Vacuum Pads type | |||||||
Code | 2618-SE5L | 2618-S7L | 3725-SE7L | 5738-SE11L | 2618-P5L | 2618-P7L | 3725-P7L | 5738-P11L | |
Suction surface size | 260 x 180 | 370 x 250 | 570 x 380 | 260 x 180 | 370 x 250 | 570 x 380 | |||
No. of rows | 5 rows | 7 rows | 7 rows | 11 rows | 5 rows | 7 rows | 7 rows | 11 rows | |
Fluid medium | Air, vacuum(※1) | ||||||||
Operating pressure range | Only for Vacuum Generator spec. | 0.3~0.7MPa | |||||||
Rated supply pressure | 0.5MPa | ||||||||
Noise level | 70㏈(A) | ||||||||
Operating vacuum pressure | Only for Vacuum Pump spec. | -100~0kPa | |||||||
Operating temp. range | 5~50℃(No freezing) | ||||||||
Theoretical suction force(※2、3) | Safety factor 1/4(Horizontal lifting)(N) | 296.1 | 277.3 | 641.6 | 1546.4 | 453.7 | 277.3 | 983.1 | 2369.5 |
Safety factor 1/8(Vertical lifting)(N) | 148.1 | 138.6 | 320.8 | 773.2 | 226.9 | 138.6 | 491.5 | 1184.7 | |
Accessory | Robot flange mounting plate, Digital Pressure Sensor with 3-color dual display, Push-in fitting for air piping | ||||||||
Fixed orifice(option) | Fixed orifice(option)or coupling orifice(option) |
||||||||
Suppresses vacuum degradation due to leakage from non-absorbed areas by attaching an orifice to regulate the flow rate | |||||||||
The coupling orifice type makes it easy to attach/detach the pad. Pads that are not required for suction can be removed thanks to the socket’s built-in stop mechanism. |
*1 “Fluid medium: vacuum” is only for vacuum pump spec.
*2 Theoretical suction force at a vacuum of -80 kPa.
*3 Do not exceed the maximum load capacity of 100 kg of the main body mounting section, including the weight of the gripper body and inertia forces during transport.
Purchase Information
Compatibility
TM Model
Support All TM Model
HW
3.2 series, S series
SW
N/A