Examples are valid for:
TMflow Software version: All
TM Robot Hardware version: All
Other specific requirements: None
Note that older or newer software versions may have different results.
Control Box : #
When the Control Box is powered off and not in use, the coin battery of the IPC mainboard can last up to three years. However, if the battery runs out, it may prevent the Control Box from powering on properly, and the BIOS settings and time will be reset.
Note : If the battery of the IPC mainboard is depleted, contact an authorized distributor.
Robot : #
If the robot has not been in use or stored for more than six months, follow these instructions for activation. Before running a project, slowly rotating the joints can increase the temperature of their reduction drives, soften the lubricant, and allow it to circulate evenly.
Activation Instructions:
- Set up and run a project on-site that allows all the joints to rotate at their maximum angles.
- After the project has begun, run at 10% speed for 10 minutes, then 30% for 1 hour and 60% for 1 hour.